2 / 8 page 81 393 300 3000 5.1 MKW2549 86 363 {50 {500 {15 MKW2547 86 363 {62.5 {625 {12 MKW2546 86 363 100 1000 15 MKW2544 86 363 125 1250 12 MKW2543 82 381 300 3000 5 MKW2542 78 30 10 264 300 3000 3.3 48 ( 36 ~ 75 ) MKW2541 81 787 300 3000 5.1 MKW2539 86 726 {50 {500 {15 MKW2537 86 726 {62.5 {625 {12 MKW2536 86 726 100 1000 15 MKW2534 86 726 125 1250 12 MKW2533 82 762 300 3000 5 MKW2532 78 40 20 528 300 3000 3.3 24 ( 18 ~ 36 ) MKW2531 81 1574 300 3000 5.1 MKW2529 86 1452 {50 {500 {15 MKW2527 86 1452 {62.5 {625 {12 MKW2526 86 1452 100 1000 15 MKW2524 86 1452 125 1250 12 MKW2523 82 1524 300 3000 5 MKW2522 78 50 30 1057 300 3000 3.3 12 ( 9 ~ 18 ) MKW2521 % (Typ.) mA (Typ.) mA (Typ.) mA (Typ.) mA mA VDC VDC @Max. Load @No Load @Max. Load Min. Max. Efficiency Reflected Ripple Current Input Current Output Current Output Voltage Input Voltage Model Number Model Selection Guide EN55022 Class A Conducted EMI Six-Sided Shielded, Metal Case RFI Free-Air Convection Cooling % 95 --- Humidity ] +125 -50 Storage Temperature ] +100 -40 Case Operating Temperature ] +60 -40 Ambient Operating Temperature Unit Max. Min. Conditions Parameter Environmental Specifications Exceeding the absolute maximum ratings of the unit could cause damage. These are not continuous operating ratings. mW 5,000 --- Internal Power Dissipation ] 260 --- Lead Temperature (1.5mm from case for 10 Sec.) VDC 100 -0.7 48VDC Input Models VDC 50 -0.7 24VDC Input Models VDC 25 -0.7 12VDC Input Models Input Surge Voltage ( 1000 mS ) Unit Max. Min. Parameter Notes : 1. Specifications typical at Ta=+25], resistive load, nominal input voltage, rated output current unless otherwise noted. 2. Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%. 3. Ripple & Noise measurement bandwidth is 0-20 MHz. 4. These power converters require a minimum output loading to maintain specified regulation. 5. Operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed. 6. All DC/DC converters should be externally fused at the front end for protection. 7. Other input and output voltage may be available, please contact factory. 8. To order the converter with Remote On/Off function, please add a suffix -RC (e.g. MKW2521-RC). 9. To order the converter with EN55022 Class A function, please add a suffix A (e.g. MKW2521A). 10. Specifications subject to change without notice. Absolute Maximum Ratings MKW2500 Series 2 MINMAX REV:0 2005/04 |
Similar Part No. - MKW2521 |
|
Similar Description - MKW2521 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |